
Sewage Treatment Power Supply
- Payment Type:
- T/T
- Incoterm:
- FOB, CIF
- Min. Order:
- 1 Bag/Bags
- Min. Order:
- 1 Bag/Bags
- Delivery Time:
- 30 Days
- Transportation:
- Ocean
- Port:
- Ningbopare
Your message must be between 20 to 2000 characters
Contact NowPlace of Origin: | shaoxing |
---|---|
Productivity: | 99999PS |
Payment Type: | T/T |
Incoterm: | FOB,CIF |
Certificate: | CE |
HS Code: | 8543300090 |
Transportation: | Ocean |
Port: | Ningbopare |
Sewage Treatment Power Supply
I. Purpose and Model Meaning:
KSF series products are aluminum alloy oxidation, hard anodic oxidation, porcelain anodic oxidation and metal, salt and water electrolysis, dedicated power supply. This equipment according to the process requirements of aluminum profile oxidation and electrolysis, and digestion and absorption of foreign advanced technology developed products.
type:
K S F A/ V
Output rated DC voltage
Output rated DC current
Cooling mode code
Use code
Device type code
Cooling mode code: A -- self-cooling F -- air cooling S -- sewage J -- oil cooling
Use code: D -- electroplating H -- electrochemistry Y -- electrophoretic paint C -- battery charging
S -- Motor speed regulation
Device type code: K - thyristor voltage regulator Z - electromagnetic voltage regulator
II. Technical parameters and characteristics:
1. Adopted standards:
National standard GB/T 3859.1-93 "Basic requirements for semiconductor converters"
JB/T 1504-93 "Power Semiconductor Devices and Rectifier Equipment"
Enterprise standard Q/SCD 001-2000 "silicon, silicon controlled rectifier standard"
2. Main technical parameters:
rated output voltage: 0 V. Rated output current: 0-A;
input power: 380 + / - 10%, 50 to 60 hz; The accuracy of stable voltage and stable current is ±1%;
soft start time adjustable 0-180 seconds; The load rating is "I", i.e., 100% rated current continuous operation.
3. Product features:
(1) The rectifier transformer adopts high magnetic conductivity cold-rolled silicon steel sheet, designed into three-phase five-column, six-phase or 12-phase unbalanced reactor output structure, energy saving than the general three-phase three-column rectifier transformer about 10%.
② It has the function of automatic voltage stabilizing and current limiting, current stabilizing and voltage limiting. The output voltage and current can be continuously adjusted.
1) Voltage stabilizing and current limiting function: when the rectifier is working in this state, if the load changes, the voltage will be stable and the current will change with the load. When the current reaches or will exceed the rated current, it is automatically in the current limiting state, that is, the maximum current does not exceed the rated current, and the voltage will drop.
2) Current stabilizing and voltage limiting function: when the rectifier is working in this state, if the load changes, the current will be stable and the voltage will change with the load. When the voltage reaches or will exceed the rated voltage, it is automatically in the voltage limit state, that is, the maximum voltage does not exceed the rated voltage, and the current drops.
③ It has high and reliable over-current and short-circuit protection function. When the load current exceeds 50% of the rated value, the rectifier will automatically block the output pulse, and the operation time is 10ms.
④ It has the function of under-voltage and phase protection. When the three-phase power line is under voltage or missing phase, the rectifier will automatically block the output pulse, and the operation time is 10ms.
(5) This product is equipped with remote control box or a centralized computer monitoring system for the use of multiple devices (need to be specified when ordering).
The main transformer adopts two vacuum dip paint or hot dip paint, drying.
The three-phase integrated trigger control board has multiple protective measures, is a novel anti-interference strong integrated double pulse trigger circuit, advanced performance, good output waveform, reliable operation, convenient debugging.
⑧ With soft start function, prevent large current impact, prolong the life of the equipment.
⑨ adopts computer standardized design, the whole machine is reasonable in structure, the control line is sealed and anticorrosive design, small in size, light in weight, easy to load and unload, easy to install and maintain, the box is sprayed with plastic treatment, anticorrosive and beautiful.
Related Keywords